TOC Torch – Total organic carbon meter

The Torch is considered a premium TOC combustion analyzer due to its many useful features and automated analytical workflow. For example, it performs serial dilutions of stock standards to form a calibration curve and automatically dilutes samples with higher concentrations than the calibration curve. Torch software has built-in diagnostics and troubleshooting capabilities.

  • Torch uses the patent-pending Static Pressure Concentration (SPC) for TOC analysis using high-temperature combustion.
  • Maintenance is simplified by a design that allows easy access to all parts of the equipment.
  • Built-in benchmark diagnostic testing – including leak testing
  • Ability to program and save oven temperatures to suit different methods
  • Static pressure condensing technology (patent pending)
  • Intellidilution feature automatically detects samples that have exceeded the selected calibration range and dilutes to stay within the selected range
  • Wide range of preset applications for analytical requirements
  • Automatic calibration eliminates the need for manual standard preparation
  • Detection level:
Carbon 50ppb to 30,000ppm
Easy access for furnace maintenance
Improved catalyst
Built-in autosampler
Increase throughput with ASM Sparge
Auto-blanking
Flow controller
Ability to mix optional titration flasks
METHOD
  • EPA 415.1, 415.3 and 9060A,
  • Standard method 5310B,
  • EP 2.2.44, ISO 8245,
  • EN 1484,
  • USP 643 (Chapter 24),
  • ASTM D2579,
  • prENV 13370,
  • AOAC 973.47
Chemistry Oxidation by combustion: From 680 °C – 1000 °C
TOC probe Non-dispersive infrared absorption (NIDR) sensor with static pressure (SPC) – patented
Analysis mode TOC (NPOC), TC-IC, TC, IC
TOC analysis Detection limit: 50 ppb

Measurable maximum concentration: 30,000 ppm

Backlog: 1.0% cross-contamination

Sample Size: 100 L to 2.0 mL

Accuracy: 1.5% RSD, ±15 ppb

Analysis time 6 – 10 minutes. 29 minutes for 3-sample TOC analysis
Carrier gas treatment Mass flow controller for instant control of carrier gas (0-500 mL/min). Automatic leak testing capabilities
Liquid handling Cylinder driver, 7-port distribution valve. Auto-dilution capability for higher TOC concentrations and difficult substrates.

The self-cleaning sample handling process cleans the injection line after each iteration.

Sample Loading Built-in autosampler
Remote controll PC, Interface via Windows™ 7 or later
Data processing Reports can be exported to XML, CSV and HTML formats

Real-time and historical graphical display of NDIR & CLD . probe data

Ability to import from CSV files and view historical results from multiple schedules on a single graphical display.

Possibility to store custom individual test methods

Priority patterns via schedule interrupt

Recalculate data, remove deviations, and control precise performance criteria (21 CFR Part 11 Compliant – Electronic Signatures and Audit Trails)

Calibration Automatic calibration from single origin standards or user calibration standards
21 CFR Part 11 Software Compliant TOC TeklinkTM software is a 21 CFR Part 11 compliant tool for your lab
Other features – Pre-programmed pointing and clicking method setting

– Automatic sample/standard dilution

– Device status/mode light

– ASM Sparge . method

– Authentication support package available

– Stir option

– Auto off/standby

– Dilution

Main application Wastewater, Industrial Wastewater, Drinking and Surface Water, Groundwater, Clean-in-Place (CIP) Valid, Sea Water
Method EPA 415.1, 415.3 and 9060A, Standard Method 5310B, EP 2.2.44, ISO 8245, EN 1484, USP 643 (Chapter 24), ASTM D2579, prENV 13370, AOAC 973.47
Certifications CE, EMC EN 50081-1 and EN 50082-1
Requirements Voltage: 100/120/240 VAC (± 10%) factory configured, Frequency: 50/60 Hz, Power: 1200VA
size 18” W x 24.5” D x 32” H, Shipping Weight 147 lbs
Gas supply Free Air Hydrocarbon and Carbon Dioxide (CO2) (with oxygen greater than 18%) with TOC <1ppm or UHP O2. Gas can be supplied from a cylinder or a TOC generator. If a TOC generator is used, the gas formed must be hydrocarbons and not contain water. To ensure the use of clean carrier gas, we recommend using a complete CO2 removal system and trapping hydrocarbons between the gas source and the analyzer.
Inlet gas pressure 65 to 100 psi
Autosampler – Accuracy: ±2.5 mm

– Reproducibility: ± 0.25 mm

– Force from the vertical stamping unit: 8.3 lbs

– Automatic wash from sample and/or wash water via integrated wash station