Online Support

TOC Fushion UV/Persulfate – Total Organic Carbon Meter

Nearly 40 years ago, Dohrmann began designing and manufacturing the premier Total Organic Carbon (TOC) Analyzer. Since joining the Tekmar family, the tradition of producing innovative laboratory TOC analyzers has continued. The Fusion Dohrmann series organic carbon analyzers are no exception. The Fusion TOC analyzer offers greater flexibility, intelligence and user-friendliness, making it ideal for the most demanding laboratory needs.

The Organic Carbon (TOC) Analyzer and TekLink™ Software provide solutions to increase sample throughput while improving the reliability of analytical data. Some of the features that increase ease of use are:
  • Unattended automatic calibration monitoring
  • Possibility of automatic dilution from master or sample standards
  • Intellidilution to automatically dilute the sample back to the calibration range.
  • Automated self-diagnostic tools including leak testing
  • 21 CFR 11 Functions – Electronic Records and Electronic Signatures (ERES) including user account management and audit trails
  • Reports can be exported in user-defined formats including metadata and versions
  • Develop a “turnkey” approach (use it now) and build a schedule
  • Massive Flow Controller (MFC) for reduced gas consumption and advanced flow control

METHOD

  • EPA 415.1- 415.3, 9060A,
  • Standard Methods 5310C, ASTM D4779 and D4839,
  • prENV 13370,
  • Cleaning Confirmation / USP Method TOC <643> / EP 2.2.44/JP
APPLICATIONS AND INDUSTRY
  • Pharmacy
  • Environment
Chemistry Photochemical oxidation via UV-Persulfate
Probe Non-dispersive infrared absorption (NIDR) sensor with static pressure (SPC) – patented
Analysis mode TOC (NPOC), TC-IC, TC, IC
Analysis Detection limit: 0.2 ppb

Measurable maximum concentration: 3,000 ppm (depends on sample volume and dilution)

Backlog: = 1.0% cross-contamination

Accuracy: = 1.0% RSD, ± 2 ppb or ± 0.02 gC

Improve the analysis process and time 4-8 minutes typical for TOC analysis; Usually 12-22 minutes for Three Sample TOC Analysis
Remote controll PC, Interface via Windows® 7 Professional or later
21 CFR Part 11 Software TOC TeklinkTM software is a 21 CFR Part 11 compliant tool for your lab
Data processing • Predefined industry standard methods and custom user defined methods

• Priority patterns via schedule interrupt

• Real-time and historical graphical display of NDIR . probe data

• Reports can be exported in XML, CSV and HTML formats

• Recalculate data, remove deviations, and control performance criteria precisely

• Ability to view results history from multiple schedules on one graphical display

Calibration • Automatic calibration from Single Stock standards or user calibration standards

• Multipoint (Linear or quadratic) and Auto-blanking

• Possibility to use one calibration curve and blank for the entire instrument “analytical range”

• Auto-check standards from Single Stock standards or user calibration standards

– Pass/Fail criteria

– Control decision when error (Pause, Recalibrate or Resume)

Other features • Automated system suitability with performance measurements

• Automatic sample/standard dilution

• Authentication support package available

• Pre-programmed point-and-click setup

• Programmable pressure and flow rate monitoring and control

• Automatic leak test

• Auto off/standby

• Self-cleaning sample handling process that cleans the reaction chambers after each iteration

• Dilution

Method EPA 415.1-415.3, 9060A, Standard Method 5310C, ASTM D4779 and D4839, and prENV 13370, Clean-up Confirmation/Method USP TOC <643>/EP 2.2.44/JP
Size 18 inches (45.7 cm) W x 24.5 inches (62.2 cm) D x 32 inches (81.3 cm) H
Carrier gas supply 99.99% pure nitrogen cylinder or 99.9% pure nitrogen generator
Inlet carrier gas pressure 65 to 100 psi