Online Support

SpectraMax® ABS/ABS Plus – Absorbance ELISA Microplate Readers

Fast and compact absorbance microplate readers for a wide range of assays without the use of filters

Filterless readers provide consistent results with steady temperature regulation

The SpectraMax® ABS and ABS Plus absorbance microplate readers provide the flexibility, sensitivity, and convenience for a wide range of assays such as ELISAs, microbial growth, and protein quantitation. Both readers feature an 8-channel read head for fast reads and a subset feature, the temperature independent PathCheck sensor that automatically normalizes and ensures accurate absorbance values by detecting pipetting errors. Combined with a wide application base, industry-leading SoftMax® Pro Software and validation tools, these readers fit in every lab and every budget.

Eliminate filters

Eliminate the need for purchasing and changing out filters with a monochromator-based wavelength selection for visible and UV-visible absorbance.

Get consistent results

Mix samples thoroughly in microplate wells with user-programmable Automix feature and monitor temperature-sensitive reactions with consistent temperature regulation from ambient to 45°C.

Integrate with ease

Measure micro-volumes: Compatible with the SpectraDrop™ Micro-Volume Microplate, enabling high-throughput measurement of low volumes (<5um) – ideal for DNA, RNA and protein quantification.

GxP Compliance Solutions – Assure data integrity and compliance for GMP/GLP laboratories.

Our comprehensive suite of proven compliance solutions for GMP/GLP labs can advance your efforts to quickly and confidently establish a compliant laboratory.

  • Best-in-class SpectraMax Microplate Readers and Washers
  • Industry-leading SoftMax Pro GxP Software – our most secure software to achieve full FDA 21 CFR Part 11 compliance
  • IQ/OQ/PM Services preserve instrument documentation in a digital and compliant format
  • Software Installation & Validation Services verify and document that required components are installed to operational specification
  • SpectraTest Validation Plates and Recertification Services tests the performance of your microplate reader to ISO 17025 standards

Abcam’s SimpleStep ELISA® kit

Unlock the full potential of your research with the powerful combination of Abcam’s SimpleStep ELISA kits and Molecular Devices’ SpectraMax® ABS Plus Microplate Reader. Together, they provide unparalleled accuracy, efficiency, and ease of use, streamlining your workflow and delivering reliable results faster than ever.

Specifications & Options of SpectraMax ABS and ABS Plus Absorbance ELISA Microplate Readers

VersaMax ELISA

SpectraMax 190 Microplate Reader

SpectraMax Plus 384 Microplate Reader

SpectraMax ABS Plus / ABS Microplate Reader

General specifications
Wavelength ranges 340 – 850 nm 190 – 850 nm 190 – 1000 nm ABS Plus: 190 – 1000 nm ABS: 340 – 850 nm
Wavelength bandwidth 2 nm 2 nm 2 nm 2 nm
Wavelength repeatability ± 0.2 nm ± 0.2 nm ± 0.2 nm ± 0.2 nm
Photometric accuracy < ±0.006 OD ±1.0%, 0-2 OD < ±0.006 OD ±1.0%, 0-2 OD Microplate: < ±0.006 OD ±1.0%, 0-2 OD Cuvette: < ±0.005 OD ±1.0%, 0-2 OD Microplate: < ±0.006 OD ±1.0%, 0-3 OD Cuvette: < ±0.005 OD ±1.0%, 0-3 OD**
Photometric precision < ±0.003 OD ±1.0%, 0-2 OD < ±0.003 OD ±1.0%, 0-2 OD < ±0.003 OD ±1.0%, 0-2 OD < ±0.003 OD ±1.0%, 0-3 OD
Stray light ≤ 0.05% at 340 nm ≤ 0.05% at 230 nm ≤ 0.05% at 230 nm ABS Plus: ≤ 0.05% at 230 nm ABS: ≤ 0.07% at 340 nm
PathCheck™ No Yes Yes Yes
Wavelength selection Monochromator tunable in 1 nm increments Monochromator tunable in 1 nm increments Monochromator tunable in 1 nm increments Monochromator tunable in 1 nm increments
Light source(s) Xenon flash lamp Xenon flash lamp Xenon flash lamp Xenon flash lamp
Read times 9 seconds 9 seconds 96-Well: 9/5 seconds 384-Well: 29/16 seconds 96-Well: 9/5 seconds 384-Well: 29/16 seconds
Plate shaking Linear Linear Linear Linear
Cuvette port No No Yes Yes
Robotics / automation Yes Yes Yes Yes
Plate type(s) 96 well plates 96 well plates 96 and 384 well plates 96 and 384 well plates
Temperature control Ambient + 5°C to 45°C Ambient + 5°C to 45°C Ambient + 5°C to 45°C Ambient + 5°C to 45°C

Pipetting errors eliminated

This reader utilizes Molecular Devices’ temperature independent PathCheck Sensor technology to measure the depth (optical pathlength) of samples in a microplate. It also allows for the elimination of standard curves.

Optimized optical path

The reader’s unique quartz fiber optic system minimizes stray light for precise readings across a microplate. The spectral resolution ensures accuracy of DNA absorbance measurements.

Eight-channel optics

The optical design of the reader enables simultaneous detection of 8 wells. The eight-channel system delivers both precision and speed across the microplate.

Dual wavelength reads

The reader delivers high performance with round-bottom, flat-bottom or half-area well plates. Dual wavelength readings report the actual absorbance at each wavelength making data analysis convenient.

Flexibility to read a variety of plate formats

SpectraMax® Absorbance Microplate Readers can run both cuvette-based and microplate reader applications on the same instrument. Read one sample or up to 384 in a single plate read using any standard cuvette, or 96- or 384-well microplate.

Validation made easy

Verify the accuracy of your absorbance measurements with the SpectraTest® ABS1 Absorbance Validation Plate, using NIST-traceable standards. Testing can be done in your own lab, on your own schedule.

Absorbance