Get the power and sensitivity of a research system with the robustness of an industrial analyzer. The Thermo Scientific™ Nicolet™ iG50 FTIR Spectrometer extends the premium performance of the Thermo Scientific™ Nicolet™ iS50, our industry-leading R&D spectrometer, onto a rugged, user-configurable FTIR platform designed for industrial applications. The system is highly configurable, compact, and rack mountable. It offers customized solutions for easy integration into your process monitoring systems, making the Nicolet iG50 spectrometer the ideal choice for OEM integration.

The Nicolet iG50 spectrometer offers high-performance to meet the broadest range of demanding applications such as Volatile Organic Compound (VOC) analysis, continuous emission monitoring (CEM) for smokestack emissions and other chemical process gas applications. With interchangeable optical and sampling interface modules, the iG50 system can be customized to fit the unique requirements of industrial process monitoring applications.In addition, the Nicolet iG50 system offers continuity from lab to plant with common formats and workflows enabling lab support when troubleshooting plant issues.

For demanding applications, the Nicolet iG50 spectrometer provides:

  • High spectral resolution needed to isolate sharp gas sample spectral bands from interfering species.
  • Excellent signal-to-noise (S/N) performance allows minimum detectable limits (MDL) of part-per-million or lower, while simultaneously measuring high-concentration components at percent level concentrations.
  • Rapid scan capabilities allow characterization of high-speed transient events.
  • Support for dual-detector collection provides flexibility for research or multi-channel monitoring.
  • Optics are housed in a compact, stainless steel enclosure which fits into a standard 19” 6U industrial rack for stable performance in manufacturing settings.
  • Dynamic alignment optical controls maintain bench stability against external vibrations and temperature swings.
  • Built-in performance verification and on-board diagnostics provide bench performance status, both visually and digitally to external DCS systems.
  • Perform your own service and maintenance using pre-aligned replacement parts, keeping downtime to an absolute minimum.
  • Worldwide network of scientists and technical support staff are available to support method development, calibration transfer, and warranty service plans.

Applications: Process liquid and gas measurements; volatile organic compound (VOC) analysis; continuous emission monitoring (CEM); at-line film analysis

Beam Splitter Options
Ge/KBr 7800–350 cm⁻¹
ZnSe 7800–550 cm⁻¹ (non-hygroscopic)
Depth (English) 16.5 in.
Depth (Metric) 42 cm
Detector Type Options
TE-cooled DLaTGS (KBr window), 12,500–350 cm⁻¹
TE-cooled DLaTGS (BaF)
Electrical Requirements 100/240 V, 50 Hz, 2.5 A
For Use With (Application) Polymers and Plastics; Analytical Services; Quality Control QA/QC; Pharmaceuticals; Education; Forensics; Gemstone Analysis
Frame Material Cover: 304 Stainless SteelBaseplate: Aluminum Alloy Steel
Height (English) 9.75 in.
Height (Metric) 25 cm
Includes Standard features:
90° Michelson Dynamically Aligned Interferometer
Polaris High Stability, Long Lifetime Mid-IR Source
1.5” (38 mm) Collimated Front Output Beam
Continuously Variable Iris Aperture
Aluminum Coated Mirrors
Validation/Attenuation Wheel
24-bit A/D Converter
USB 2.0 Interface
Helium Neon (HeNe) reference laser
Configurable front or side collimated beam output
Continuous On-Board Hardware Monitoring
User replaceable components: Source, Laser, Detector, Power Supply, Electronics Module
Automated Performance Verification Testing
Thermo Scientific™ OMNIC™ Software
Interface PC USB 2.0
Model Nicolet iG50 Spectrometer – Base spectrometer, front collimated beam output, no sampling interface. Options include Ge/KBr or ZnSe beamsplitter and CaF₂ coated KBr or ZnSe windows. Right side beam output optional.
Nicolet iG50 Sampling Interface – Front-mounted Standard or Extended. Purgeable and accommodates full-size accessories. Standard plate supports TE-DTGS detectors. Compatible with rack mount enclosures. Extended Sample Plate compatible with LN2-cooled MCT and other Nicolet iS50 compatible detectors.
Nicolet iG50 External Detector Module – Purgeable stand-alone module including detector focusing mirror. No sampling interface. Must select collimated or focused beam input.
Output Beam Output Options: Front or right side
Product Type Nicolet iG50 FTIR Spectrometer
Sensitivity Ordinate Linearity 0.07%T
Wavenumber Precision better than 0.01 cm⁻¹
Scan Velocity (15 values): 0.158 to 6.28 cm/sec
Source Type Polaris™ High Stability, Long Lifetime Source (5 year warranty)
Spectral Range 7800 to 350 cm⁻¹ (KBr beamsplitter)
6000 to 650 cm⁻¹ (ZnSe beamsplitter)
Spectral Resolution 0.5 cm⁻¹
Weight (English) 63 lb
Weight (Metric) 29 kg
Width (English) 17.75 in
Width (Metric) 45 cm
Performance Verification Automated Performance Verification Testing
Voltage 100/240 V
Unit Size Each